AUTOCLAVE –HORIZONTAL CYLINDRICAL | AUTOCLAVES | ACRYLISER | ISO 9001-2000
  

HOMEAUTOCLAVES  CONTACT US

                                                                                                                                   

A U T O C L A V E   F O R   A C R Y L I Z A T I O N

AUTOCLAVE FOR ACRYLIZATION

 

R & D PRODUCT FOR RUBBER INDUSTRY

Incorporating Indigenously Developed Technological Invention for completely Eliminating Water Hammering

 

 Model: AUTOCLAVE_RND

Reproduces Ageing condition in fast motion

         Application: Suitable for rubber compound.

          Used on samples for studying:

               1.   Temperature and Humidity ageing at different time and temperature.

       2.  Accelerated ageing gives idea about the characteristics which lead to withhold in particular environment and for how long.

 Salient Features:

ð  Fully Automatic Programmable 

ð  Chamber Type / Size: Vertical / As per Custom Requirement

ð  Recommended Capacities: 50, 75, 90 Liters. Larger capacities can be manufactured.

ð  Temp. Range 100O to 150O C. Time 00 To 144 Hrs.  (or As Per Custom Specs)

ð  Rigorous Temp Control: +/- 2o C throughout the process.

ð  2 Line LCD For Display of Messages And Faults.

ð  Fully Stainless Steel Double Walled With Chamber And Jacket of SS 304 And Ceramic wool Insulation In-Between.

ð  SS 304 Boiler Tank and Control Box

ð  On line Auto Water Filling with Zero Water Hammering. The process is not disrupted.

ð  Vacuum Breaker, Pressure Gauge And Spring Loaded Safety Valve.  M. S. Powder Coated Tubular Stand.

ð  Condensate Line

ð   “S” CLASS, Power Failure Memory. Self Diagnostic Software. Password Protection & Reporting.

 Specifications:

Operating Voltage:                                         230 VAC, 1 Ø or 415 VAC, 50 Hz, 3Ø

Power Rating:   Heater:                                6 K Watt or Depending upon size.

                        Control:                                    50 Watt

Water Filling:                                                  Auto On-line without disrupting process

Water Removal:                                             Manual

Condensate Line                                          Steam Trap of ½” BSP or larger connection

Indication on Display:                                   Last Program Successfully Run * Set/Actual Temp (o C) &

                                                       Time (Hrs) * Process Alerts * Process Over * Process Report *

                                                       Water Cut off Indication * Water Re-fill stages

Charge Types                                                Rubber Compound

Air Removal by                                              Pressure Pulses (“S” Class)

Pressure Pulses                                          1

Pneumatic Test Pressure                  1.5 Times Max Operating Pressure

Max Operating Pressure                   2.1 Barg

Reporting                                        Total Time Taken * No. of Power Failures

 OPTIONAL: (AT EXTRA COST) 

ð  4 Line LCD in lieu of 2 Line LCD

ð  MOC: SS 316 In Lieu of SS 304 for Chamber and Boiler

ð  Digital Display of Pressure In Lieu of Needle Gauge.

ð  Connectivity to PC / SCADA operation

ð  Logging:

80 Column Dot Matrix Printer

Logs Temperature / Pressure (Vacuum) data at interval of 1 minute from Process Start to Process End. This allows Analysis of the Process. Saves Log till next cycle run. 

ð  Authorization & Detailed Reporting:

User Authorization; Date & Time Edit By Admin Password

Detailed Reporting And Saving Data of Last 5 Batch Runs

Option To View Or Print Report From Start Menu.

Optional Printing

80 Col Dot Matrix Printer if Logging Opted for. Else Mini Thermal Printer 

Parameters Reported:

Operator Id * Date & Time Of Batch Start * Cycle: Wet Or  Wet & Dry * Sterilization Temperature * Sterilization Time * Temperature At Different Pressure Pulses * No. Of Power Failures * Process Time Taken * Power Consumed During The Process * Process Result: Success, Aborted(User Stopped) Or Unsuccessful Due To Process Failure With Fault Indication.

Can also Generate Report for Customized Parameters in Custom Format.

ð  Indicative Report Format (if Logging opted for)

COMPANY’S NAME

 Printed On: 17.7.2011

 

SUMMARY REPORT

Saved Report

 

Batch No.

 

Sterilization Temp o C

 

Date

 

Sterilization Time (Mins)

 

Operator Id

 

Pre Vacuum?

 

Time Start

 

No. of Vacuums

 

Vacuum No.

Temperature o C / Vacuum (psia)

No. of Power Failures

 

1

 

End Time / Date

 

2

 

Power Consumed KWhr

 

3

 

Process Result

 

           

END OF REPORT 

ð  Note: This is summary report of last 5 cycle runs saved in the controller. This can be retrieved and printed from Main Menu 

 

COMPANY’S NAME

 

 

STERILIZATION REPORT

On Line Report

 

Batch No.

 

Sterilization Temp o C

 

Date

 

Sterilization Time (Mins)

 

Operator Id

 

Pre Vacuum?

 

Time Start

 

No. of Vacuums

 

           

 PROCESS LOG 

TIME STAMP

Temperature o C

Pressure psia

Pressure (psig) / Vacuum (Torr)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  OTHER DETAILS  

Vacuum No.

Temperature o C / Vacuum (psia)

No. of Power Failures

 

1

 

End Time / Date

 

2

 

Power Consumed KWhr

 

3

 

Process Result

 

Pre Vacuum

 

Process Fault, if any

 

  END OF REPORT 

 ð  Notes: The above format can change based on printer’s programming code lines

                                       Batch No. is assigned from 1 to 255 and revolves to 1 after 255. 

 Design & Specifications Subject to Change without Notice

 

Copyright © 2009 PUNEET INDUSTRIES. All rights reserved.