Micro Computerised control with LCD screen for messages and
With Unique
-
Power failure memory : auto re-starts process on power resumption.
User friendly:
-
single key press starts & completes process on its own
-
supervision not required
-
displays process over message on completion
-
blinking light for user attention on message on screen
-
help messages on screen
-
Protection from tampering of set parameters: Password incorporated
-
User programmable : Temp: 121 to 135 deg. C, Time: 15 to 59 mins
-
Safety valve.
-
Front Loading type construction for ease of operation
-
Robust construction: stainless steel claving chamber with M. S. Powder Coated Control body.
-
Safety: process power configured in cut-off mode in its steady state of rest
-
Self Diagnostic Software identifies process faults and displays on screen e.g.: Sensor error, Heating not progressing etc
-
Versatility: permits stop & edit at any time during process run
-
Provision to Run Wet, or Wet and Dry Both Cycles |

|
|
SPECIFICATIONS |
| Power Rating – Heater |
2000 Watts |
| Control System |
Less than 50 Watts |
| Water Filling |
Manual |
| Operating Voltage |
230 Volts +/- 10%, 50 Hz, 1Phase |
| Control Type |
Micro-Computerised control with LCD display |
| Protection |
Password Protection against un-authorized tampering |
| Memory |
Stores the process condition at power failure and continues on Power resumption |
| Alerts Indication |
By Blinking Light |
| Wet Temp Set Range |
121 to 135 Degree Centigrade |
| Dry Temp Value |
Fixed |
| Set Time Range |
15 to 59 Minutes |
| Display |
2 x 16 Liquid Crystal Display (2 Rows x 16 Charatcers) |
| Indication on Display |
- Set/Actual Temp in Deg. Centigrade
- Set Time in MM
- Process Alerts
- Process Over
|
| |
|
POWER FAILURE MEMORY – HOW IT WORKS?
Once the “Run” key is pressed, the process starts and micro-controller continuously monitors the process parameters and saves them in internal memory. At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.
On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption. If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure.
This is done automatically.
WHY PASSWORD?
Password is required only to edit process parameters like set temperature time. Password is not required to Run the Process with previously set values.
This facilitates the control of Supervisor or H.O.D over process parameters set values and permits the Junior staff / student to run the process without need of presence to Supervisor / H. O. D.
WHAT IF PASSWORD FORGOTTEN?
If the user has forgotten Password, then the default Password can be loaded through Key Switch on the right face of the control panel.
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
|