CAST DUPLICATOR
- 3 kg capacity – ideal for the day’s work
- Computerised control of process including heating, cooling,
stirring, and timing.
- Large LCD screen for digital display of messages and process
status
User friendly :
- Single key press starts & completes process on its own
- Supervision not required
- Displays “process over“ message on completion
- Blinking light draws user attention for message on screen *
flashes help
- messages on screen to guide user
- User programmable temperature and time
- Stirrer on/off facilitated by key switch
- Prepares & maintains duplicating gel in ready to use form for
indefinite period.
- Low power uniform heating from all sides prevents burning of
gel
- Low speed stirrer ensures homogenous mixing without splashing
- Convenient outlet for ease of dispensing
- Ultra low power continuous heating of outlet ensures gel does
not solidify in outlet system
- Protection from tampering of set parameters: Password
incorporated
- Power failure memory : auto re-starts process on power
resumption.
- Robust unit: fully stainless steel body.
- Safety: power configured in cut-off mode in its natural steady
state of rest
- Versatility: permits stop & edit at any time during process on
|
 |
|
|
SPECIFICATIONS |
|
Construction |
Stainless Steel |
|
Gel Filling |
Small pieces of Gel filled Manually |
|
Capacity |
3 Kg |
|
Power Rating – Heater |
250 Watts |
|
Control |
Less than 50 Watts |
|
Operating Voltage |
230 Volts +/- 10%, 50 Hz, 1Phase |
|
Controller Type |
Micro Computerised with LCD Display |
|
Display Type |
2 x 16 Liquid Crystal Display (2 rows x 16 characters) |
|
Protection |
Password Protection against un-authorized tampering |
|
Power Failure Memory |
Built-in |
|
Process |
2 Time – Temp cycles with Auto Changeover |
|
Default Settings |
92deg. C for 5 mins; 55 Deg.C indefinitely |
|
Set Temperature / Time |
By various keys on keyboard |
|
Temp / Time Set Range |
0 to 100 Deg C. / 0 to 9:59 (H:MM) |
|
User Cycles |
Programmable through front panel key switches |
|
Alert / Message Indication |
Blinking Light with display on screen |
|
Screen Display |
1) Help Messages
2) Error Messages,
3) Set and Actual Temp,
4) Set and Balance Time,
5) Cycle Running,
6) Process Over Message |
|
Process End |
Auto OFF with Message |
POWER FAILURE MEMORY – HOW IT WORKS?
Once the “Run” key is pressed, the process starts and
micro-controller continuously monitors the process parameters and
saves them in internal memory. At Power Failure these process
parameters are stored in Memory provided on board. This memory is
non-volatile and can be retained for a long period.
On resumption of power, the controller restarts and retrieves the
temperature value at power failure and compares it with actual
value on power resumption. If the drop in temperature is more than
10% of the value at power failure, then the processor re-starts
the process from beginning and if f the drop in temperature is
less than 10% of the stored value, then the process resumes from
where it stopped at power failure.
This is done automatically.
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
|