PRODUCTS>Auto Clave - Front Loading 
FEATURES:
Micro computerised control with LCD
screen for messages and
With Unique
Power failure memory :
auto re-starts process on power resumption.
User friendly:
single key press starts & completes process on its own * supervision
not required * displays “process over” message on completion * blinking
light for user attention on message on screen * help messages on screen *
Automatic release of steam on completion of wet cycle
Password Protection: Protects tampering of set parameters:
User programmable : Temp: 121 to 130 deg. C, Time: 15 to 59 mins,
Cycle: Wet or Wet and Dry
Ease of Operation: Front Loading
Robust construction: stainless steel claving chamber with M. S. Powder Coated
body
Safety: process power configured in cut-off mde in its steady state of rest
Versatility: permits stop & edit at any time during process
run.
Option for Dry Cycle.
Self Diagnostic Software:
Identifies process faults and displays on
LCD screen
Specifications:
Power Rating – Heater 1000 Watts
Drum Size
10"(D) x 10" (L)
Control System
Less than 50 Watts
Water Filling
Manual
Operating Voltage 230 Volts
+/- 10%, 50 Hz, 1Phase
Control Type
Micro-computerised control with LCD display.
Protection
Password Protection against un-authorized tampering
Memory
Saves Process condition at power failure and continues
on Power
Resumption.
Alerts Indication
By Blinking Light.
Temp Set Range 121 to 130
Degree Centigrade
Set Time Range 15 to 59
Minutes
Cycles
User programmable - only wet cycle or wet and dry cycles
Display
2 x 16 Liquid Crystal Display (2 Rows x 16 Characters)
Indication on Display
Set/Actual Temp in Deg. Centigrade * Set Time in MM*
Process Alerts * Process Over
POWER
FAILURE MEMORY – HOW IT WORKS?
Once
the “Run” key is pressed, the process starts and
micro-controller continuously monitors the process
parameters and saves them in internal memory. At Power
Failure these process parameters are stored in Memory
provided on board. This memory is non-volatile and can
be retained for a long period.
On resumption of power, the controller
restarts and retrieves the temperature value at power
failure and compares it with actual value on power
resumption. If the drop in temperature is more than 10%
of the value at power failure, then the processor
re-starts the process from beginning and if f the drop
in temperature is less than 10% of the stored value,
then the process resumes from where it stopped at power
failure.
This is done automatically.
WHY
PASSWORD?
Password is required only to edit
process parameters like set temperature time. Password
is not required to Run the Process with previously set
values.
This facilitates the control of
Supervisor or H.O.D over process parameters set values
and permits the Junior staff / student to run the
process without need of presence to Supervisor / H. O.
D.
WHAT IF
PASSWORD FORGOTEN?
If the user has forgotten Password, then
the default Password can be loaded through Key Switch on
the right face of the control panel.
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
|