PRODUCTS>Bath - Std

FEATURES:
Ideal for study of
teetth movement
Micro computerised control with LCD screen for
messages.
User friendly:
single key press
starts & completes process on its own *
supervision
not required * displays “process
over”
message on completion *
blinking light
draws user attention for message on
screen * flashes help
messages on screen
to guide user
User programmable:
time
Protection from tampering of set parameters:
Password
incorporated
Power failure memory : auto
re-starts
process on power resumption.
Self diagnostics
software:
displays
fault condition
on screen making repairs easy.
Robust unit
fully stainless
steel
body.
Safety: process power configured in
cut-off
mde in its natural steady state of rest
Versatility: permits
stop & edit
at any time during process
run
Tank
Size 16” x 12” x 12”
(approx)
Power Rating –
Heater 2000 Watts
Control
System Less than 50 Watts
Water
Filling Manual
Operating
Voltage 230 Volts +/- 10%, 50 Hz,
1Phase
Control
Type Micro-computerised control
with LCD display.
Protection Password
Protection against un-authorized tampering
Memory Stores the
process condition at power failure and continues on
Power resumption.
Alerts By Visual
indications.
Set
Temperature By various keys on
keyboard.
Temp Set
Range 0 to 99 Degree Centigrade
Time Set
Range 0 to 9 Hrs 59 Mins
Display 2 x 16 Liquid
Crystal Display (2 Rows x 16 Charatcers)
Display
Indication Set/Actual Temp in Deg. C *
Timer ON / OFF * Set Time in H:MM *
Process
Alerts * Process Over
POWER
FAILURE MEMORY – HOW IT WORKS?
Once
the “Run” key is pressed, the process starts and
micro-controller continuously monitors the process
parameters and saves them in internal memory. At
Power Failure these process parameters are stored in
Memory provided on board. This memory is
non-volatile and can be retained for a long period.
On
resumption of power, the controller restarts and
retrieves the temperature value at power failure and
compares it with actual value on power resumption.
If the drop in temperature is more than 10% of the
value at power failure, then the processor re-starts
the process from beginning and if f the drop in
temperature is less than 10% of the stored value,
then the process resumes from where it stopped at
power failure.
This
is done automatically.
WHY PASSWORD?
Password is required only to edit process parameters
like set temperature time. Password is not required
to Run the Process with previously set values.
This
facilitates the control of Supervisor or H.O.D over
process parameters set values and permits the Junior
staff / student to run the process without need of
presence to Supervisor / H. O. D.
WHAT
IF PASSWORD FORGOTEN?
If
the user has forgotten Password, then the default
Password can be loaded through Key Switch on the
right face of the control panel.
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |