Manufacturers of Quality Dental Equipments

PRODUCTS>Bath - Std                                   

FEATURES:

Ideal for study of teetth movement

Micro computerised control with LCD screen for messages.

User friendly:

        single key press starts & completes process on its own * supervision not required * displays “process over” message on completion * blinking light draws user attention for message on screen * flashes help messages on screen to guide user

User programmable:  time

Protection from tampering of set parameters: Password incorporated

Power failure memory : auto re-starts process on power resumption.

Self diagnostics software:

        displays fault condition on screen making repairs easy.

Robust unit fully stainless steel body.

Safety:   process power configured in cut-off  mde in its natural steady state of rest

Versatility:  permits stop & edit  at any time during process run

 Specifications:

 Tank Size                            16” x 12” x 12” (approx)

Power Rating – Heater       2000 Watts

Control System                   Less than 50 Watts

Water Filling                       Manual

Operating Voltage               230 Volts +/- 10%, 50 Hz, 1Phase

Control Type                      Micro-computerised control with LCD display.

Protection                           Password Protection against un-authorized tampering

Memory                              Stores the process condition at power failure and continues on Power resumption.

Alerts                                  By Visual indications.

Set Temperature                 By various keys on keyboard.

Temp Set Range                 0 to 99 Degree Centigrade

Time Set Range                  0 to 9 Hrs 59 Mins

Display                               2 x 16 Liquid Crystal Display   (2 Rows x 16 Charatcers)

Display Indication              Set/Actual Temp in Deg. C *  Timer ON / OFF * Set Time in H:MM *

                                            Process Alerts *  Process Over

 POWER FAILURE MEMORY – HOW IT WORKS?

 Once the “Run” key is pressed, the process starts and micro-controller  continuously monitors the process parameters and saves them in internal memory.  At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.

 On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption.  If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure.

 This is done automatically.

WHY PASSWORD?

Password is required only to edit process parameters like set temperature time. Password is not required to Run the Process with previously set values.

This facilitates the control of Supervisor or H.O.D over process parameters set values and permits the Junior staff / student to run the process without need of presence to Supervisor / H. O. D.

 WHAT IF PASSWORD FORGOTEN?

 If the user has forgotten Password, then the default Password can be loaded through Key Switch on the right face of the control panel.  

              DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE