Manufacturers of Quality Dental Equipments

PRODUCTS>Burn Furnace - 5 Programs           

STD MUFFLE: 4” X 4” X 8”.                              LARGE MUFFLE: 5” X 5” X 7”

Micro computerised control with Large LCD screen for messages & values and

With Unique

Power failure memory:    auto re-starts process on power resumption.

Versatility:  permits stop & edit  at any time during process on

User friendly:

            single key press starts & completes process on its own * supervision not required * displays “process over” message on completion * blinking light draws user attention to messages on screen.

5 programmes each with 3 user programmable steps

Each step programmable for:  hold temperature  *  hold time  *  heating rate

Linear Heating Rate programmable range  0 – 9 Degree C

Hold Time programmable range: 0 to 99.9 Mins

Maximum Temperature programmable range: 0 to 999 degree C

Safety:   power configured in cut-off  mode in its natural steady state of rest

Construction:  M.S. Powder coated body. 

Specifications:

Size                                                            :   400 (L) x 370 (D) x 490 (H) mm

Weight                                                        :   Approx. 25 Kg

Operating Voltage                                     :   230 Volts AC,  50 Hz, 1Phase, Stabilised

Power Consumption – Std / Large            :   1700 / 3200 Watts

Control Power                                            :   Less than 50 Watts

Control Unit                                                :   Modular type firmly mounted inside the body

Max. Temp Withstanding.                         :   1000 Deg. Centigrade continuous

Programming                                              :   By Front Panel Key Switches 

Soak Temperature  Deg. C          :  3 set points in range 0 - 500; 501 - 700; 701 - 999

            Soak Time                                      :   0 to 99.9 Minutes in each set point

            Rate of Rise of Temp                    :   0 to 9 Deg. C/minn

Indication                                                    :   4 Line 20 characters Liquid Crystal Display Screen

 

POWER FAILURE MEMORY – HOW IT WORKS?

Once the “Run” key is pressed, the process starts and micro-controller  continuously monitors the process parameters and saves them in internal memory.  At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.

On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption.  If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure.

This is done automatically.

      WHY PASSWORD?

Password is required only to edit process parameters like set temperature time. Password is not required to Run the Process with previously set values.

This facilitates the control of Supervisor or H.O.D over process parameters set values and permits the Junior staff / student to run the process without need of presence to Supervisor / H. O. D.

WHAT IF PASSWORD FORGOTEN?

If the user has forgotten Password, then the default Password can be loaded through Key Switch on the right face of the control panel..

DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE