PRODUCTS>Burn Furnace - 5 Programs 
STD MUFFLE: 4” X 4” X
8”.
LARGE MUFFLE: 5” X 5” X 7”
Micro computerised control with Large LCD screen for
messages & values and
With Unique
Power failure memory:
auto
re-starts
process on power resumption.
Versatility:
permits
stop & edit
at any time during process
on
User friendly:
single key press starts & completes
process on its own * supervision not required * displays
“process
over”
message on completion *
blinking light draws
user attention to messages on screen.
5
programmes each with 3 user programmable steps
Each
step programmable for: hold temperature * hold time
* heating rate
Linear
Heating Rate programmable range 0 – 9 Degree C
Hold
Time programmable range:
0 to 99.9 Mins
Maximum Temperature programmable range: 0 to 999 degree
C
Safety: power configured in
cut-off
mode in its natural steady state of rest
Construction: M.S.
Powder coated body.
Specifications:
Size
: 400 (L) x 370 (D) x 490 (H) mm
Weight
: Approx. 25 Kg
Operating Voltage
: 230 Volts AC, 50 Hz, 1Phase,
Stabilised
Power Consumption – Std /
Large : 1700 / 3200 Watts
Control
Power :
Less than 50 Watts
Control
Unit :
Modular type firmly mounted inside the body
Max. Temp
Withstanding. : 1000 Deg.
Centigrade continuous
Programming
: By Front Panel Key Switches
Soak Temperature Deg. C : 3 set points in range
0 - 500; 501 - 700; 701 - 999
Soak
Time : 0 to 99.9
Minutes in each set point
Rate of Rise of
Temp : 0 to 9 Deg. C/minn
Indication
: 4 Line 20 characters Liquid Crystal
Display Screen
POWER FAILURE MEMORY – HOW IT WORKS?
Once the “Run” key is pressed, the
process starts and micro-controller continuously
monitors the process parameters and saves them in
internal memory. At Power Failure these process
parameters are stored in Memory provided on board. This
memory is non-volatile and can be retained for a long
period.
On resumption of power, the controller
restarts and retrieves the temperature value at power
failure and compares it with actual value on power
resumption. If the drop in temperature is more than 10%
of the value at power failure, then the processor
re-starts the process from beginning and if f the drop
in temperature is less than 10% of the stored value,
then the process resumes from where it stopped at power
failure.
This is done automatically.
WHY PASSWORD?
Password is required only to edit process
parameters like set temperature time. Password is not
required to Run the Process with previously set values.
This facilitates the control of
Supervisor or H.O.D over process parameters set values
and permits the Junior staff / student to run the
process without need of presence to Supervisor / H. O.
D.
WHAT IF PASSWORD FORGOTEN?
If the user has forgotten Password, then
the default Password can be loaded through Key Switch on
the right face of the control panel..
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT
NOTICE
|