PRODUCTS>De-Wax 
Micro computerized control with LCD screen for messages
& values and
With Unique
Power failure memory:
auto
re-starts
process on power resumption.
Versatility:
permits
stop & edit
at any time during process
on
User friendly:
single key
press starts & completes process on its own *
supervision not
required
* displays “process over“ message on completion *
blinking
light
draws user attention for message on
screen * flashes
help messages
on
screen
to guide user
User programmable time -
temp cycle.
Protection from tampering of set parameters:
Password
incorporated
Self diagnostics
software: displays
fault
condition
on
screen making repairs easy.
Robust unit:
fully stainless steel
body.
Safety: power configured in
cut-off
mode in its natural steady state of rest
Specifications:
Construction
Stainless Steel
Tank Sizes (Usable)
16x12x 9” approx
Water
Filling Manual
Power Rating –
Heater 2000 Watts
Control Less than 50 Watts
Operating
Voltage 230 Volts +/- 10%, 50
Hz, 1Phase
Controller
Type Micro Computerized
with LCD Display
Display Type
2 x 16 Liquid Crystal
Display (2 rows x 16 characters)
No. of flasks
accommodated
8 in a layered manner
Protection
Password Protection against un-authorized tampering
Power Failure
Memory Built-in
Process Programmable
Time – Temp cycles with Auto Off
Default
Cycle 92deg. C for 5
mins with Timer Programmed to “OFF “
Set Temperature /
Time By various keys on keyboard.
Temp / Time Set
Range 0 to 99 Deg C. / 0 to 9:59 (H:MM)
User
Cycles Programmable
through front panel key switches
Alert / Message
Indication Blinking Light with display on
screen
Screen
Display 1) Help Messages,
2) Error Messages, 3) Set and Actual
Temp, 4) Set and Balance Time, 5) Pre Cure / Curing
Cycle
Running, 6) Temp Rise / Fall, 7) Temp Bar Graph,
8)
Process Over Message 9) Heater Status
Process
End Auto OFF with
Message and Alerts
POWER
FAILURE MEMORY – HOW IT WORKS?
Once the
“Run” key is pressed, the process starts and
micro-controller continuously monitors the process
parameters and saves them in internal memory. At Power
Failure these process parameters are stored in Memory
provided on board. This memory is non-volatile and can
be retained for a long period.
On
resumption of power, the controller restarts and
retrieves the temperature value at power failure and
compares it with actual value on power resumption. If
the drop in temperature is more than 10% of the value at
power failure, then the processor re-starts the process
from beginning and if f the drop in temperature is less
than 10% of the stored value, then the process resumes
from where it stopped at power failure.
This is
done automatically.
WHY
PASSWORD?
Password
is required only to edit process parameters like set
temperature time. Password is not required to Run the
Process with previously set values.
This
facilitates the control of Supervisor or H.O.D over
process parameters set values and permits the Junior
staff / student to run the process without need of
presence to Supervisor / H. O. D.
WHAT IF
PASSWORD FORGOTEN?
If the
user has forgotten Password, then the default Password
can be loaded through Key Switch on the right face of
the control panel.
DESIGN