PRODUCTS>Hot
Air Steriliser_Dry Heat Oven

Micro computerized control with LCD screen for messages
& values and
With Unique
Power failure memory:
auto
re-starts
process on power resumption.
Versatility:
permits
stop & edit
at any time during process
on
User friendly:
single key press
starts & completes process on its own *
supervision
not
required *
displays “process
over”
message on completion *
blinking light
draws user
attention for message on screen * flashes help
messages on
screen to guide user
User programmable time - temp cycle.
Bult-in default cycle.
Protection from tampering of set parameters:
Password
incorporated
Self diagnostics
software: displays
fault condition
on screen making repairs easy.
Robust unit
fully stainless steel
body.
Safety: process power configured in
cut-off
mde in its natural steady state of rest
Construction
:Stainless Steel Chamber with M. S. Powder Coated outer
body
Power Rating – Heater
500 Watts
Control
System Less than 50 Watts
Operating
Voltage 230 Volts +/- 10%, 50 Hz, 1Phase
Control
Type Micro-computerized control
with LCD display.
Protection Password Protection
against un-authorized tampering
Memory Built – in Power
Failure Memory.
Alerts By Visual
indications.
Set
Temperature By various keys on keyboard.
Temp Set
Range 0 to 175 Degree Centigrade
Time Set Range
0 to 9 Hrs 59 Mins
Display 2 x 16 Liquid
Crystal Display (2 Rows x 16 Charatcers)
Display
Indication Set/Actual Temp in Deg. C * Set
Time in H:MM * Process Alerts
* Process
Over
POWER
FAILURE MEMORY – HOW IT WORKS?
Once the
“Run” key is pressed, the process starts and
micro-controller continuously monitors the process
parameters and saves them in internal memory. At Power
Failure these process parameters are stored in Memory
provided on board. This memory is non-volatile and can
be retained for a long period.
On
resumption of power, the controller restarts and
retrieves the temperature value at power failure and
compares it with actual value on power resumption. If
the drop in temperature is more than 10% of the value at
power failure, then the processor re-starts the process
from beginning and if f the drop in temperature is less
than 10% of the stored value, then the process resumes
from where it stopped at power failure.
This is
done automatically.
WHY PASSWORD?
Password
is required only to edit process parameters like set
temperature time. Password is not required to Run the
Process with previously set values.
This
facilitates the control of Supervisor or H.O.D over
process parameters set values and permits the Junior
staff / student to run the process without need of
presence to Supervisor / H. O. D.
WHAT IF
PASSWORD FORGOTEN?
If the
user has forgotten Password, then the default Password
can be loaded through Key Switch on the right face of
the control panel.
DESIGN