Micro computerized control with LCD screen for messages & values and

With Unique

Power failure memory:    auto re-starts process on power resumption.

Versatility:  permits stop & edit  at any time during process on

User friendly:

        single key press starts & completes process on its own * supervision not

        required * displays “process over” message on completion * blinking light

        draws user attention for message on screen * flashes help messages on

        screen to guide user

User programmable time  - temp cycle.   Bult-in default cycle.

Protection from tampering of set parameters: Password incorporated

Self diagnostics software: displays fault condition on screen making repairs easy.

Robust unit fully stainless steel body.

Safety:   process power configured in cut-off  mde in its natural steady state of rest

 Specifications:

 Construction                      :Stainless Steel Chamber with M. S. Powder Coated outer body

Power Rating – Heater       500 Watts

Control System                   Less than 50 Watts

Operating Voltage               230 Volts +/- 10%, 50 Hz, 1Phase

Control Type                      Micro-computerized control with LCD display.

Protection                           Password Protection against un-authorized tampering

Memory                              Built – in Power Failure Memory.

Alerts                                  By Visual indications.

Set Temperature                 By various keys on keyboard.

Temp Set Range                 0 to 175 Degree Centigrade

Time Set Range                  0 to 9 Hrs 59 Mins

Display                               2 x 16 Liquid Crystal Display   (2 Rows x 16 Charatcers)

Display Indication             Set/Actual Temp in Deg. C *  Set Time in H:MM *  Process Alerts

                                           *  Process Over

 POWER FAILURE MEMORY – HOW IT WORKS?

Once the “Run” key is pressed, the process starts and micro-controller  continuously monitors the process parameters and saves them in internal memory.  At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.

On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption.  If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure.

This is done automatically.

      WHY PASSWORD?

Password is required only to edit process parameters like set temperature time. Password is not required to Run the Process with previously set values.

This facilitates the control of Supervisor or H.O.D over process parameters set values and permits the Junior staff / student to run the process without need of presence to Supervisor / H. O. D.

WHAT IF PASSWORD FORGOTEN?

If the user has forgotten Password, then the default Password can be loaded through Key Switch on the right face of the control panel.

      DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE